Function
|
Measurement of AC leakage current, AC current and on-line AC current
|
|
Power
|
DC3V Button-type battery LR-44×2 or SR-44×2
|
|
Test Mode
|
Clip-on CT,integral mode
|
|
Display Mode
|
Four Bits LCD display
|
|
Dimension
|
Width × Height× Thickness:
64mm×160mm×23mm
|
|
LCD Dimension
|
35mm×21.5mm;display domain:32mm×15mm
|
|
Clamp Mouth
|
φ40mm
|
|
Sampling Rate
|
about 2 times/s
|
|
Range
|
0.00mA~300.0A(50/60Hz)
|
|
Resolution
|
- 4 -0.01mA
|
|
Measuring range
|
30mA/300mA,30A/300A,second-range manual switch,Automatic switch in all ranges
|
|
Measurement accuracy
(below 23C±1C,
70%RH)
|
0.00mA~9.99mA:±1.2%±5dgt
|
|
10.0mA~300.0mA: ±1.5%±5dgt
|
|
0.00A~9.99A:±1.2%±5dgt
|
|
10.0A~99.9A: ±1.5%±5dgt
|
|
100.0A~199.9A: ±2%±5dgt
|
|
200.0A~300.0A:±4%±5dgt
|
|
Line voltage
|
Line test under AC600V
|
|
Data Storage
|
60 groups, “FU” symbol flickering means storage is full
|
|
Peak Holding
|
Peak value capture and holding function, press HOLD button continually to show peak value in the course of testing.
|
|
Data Holding
|
Data holding function:displayed by “DH” symbol
|
|
Overflow display
|
- 5 -Outrange overflow display:displayed by “OL” symbol
|
|
Automatic shutdown
|
After starting up the leaker for 5 minutes, it will shut down automatically to reduce battery consumption.
|
|
Battery voltage
|
When battery voltage reduced to 2.5V~2.7V, battery low voltage symbol will filker to remind replacing battery; at this time, measurement accuracy will decrease.
|
|
Leaker Quality
|
About 120g(with battery)
|
|
Rating Power
|
about 5mW
|
|
Working temperature and humidity
|
-0C~40C;below 80%rh
|
|
Storage temperature and humidity
|
-10C~60C;below 70%rh
|
|
Insulation strength
|
AC2kV/rms (between core and box)
|
|
Applicable safety rules
|
IEC1010-1、IEC1010-2-032、pollution, etc 2、CAT Ⅲ(600V)
|